Lanes, Volumes, Timings

1: Far Hills Ave & Old River Trl/Springhouse Rd

01/07/2023
EBL direction EBT direction EBR direction WBL direction WBT direction WBR direction NBL direction NBT direction NBR direction SBL direction SBT direction SBR direction
Lane Group EBL EBT EBR WBL WBT WBR NBL NBT NBR SBL SBT SBR
Lane Configurations Thru Left Right Left Thru Right Left Thru Right Left Thru Right
Traffic Volume (vph) 18 5 20 13 5 78 10 808 8 58 363 9
Future Volume (vph) 18 5 20 13 5 78 10 808 8 58 363 9
Ideal Flow (vphpl) 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900
Storage Length (ft) 0 170 0 0 205 0 150 0
Storage Lanes 0 1 0 0 1 0 1 0
Taper Length (ft) 25 25 50 50
Lane Util. Factor 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.95 0.95 1.00 0.95 0.95
Frt 0.850 0.891 0.999 0.996
Flt Protected 0.962 0.993 0.950 0.950
Satd. Flow (prot) 0 1792 1583 0 1632 0 1787 3571 0 1752 3491 0
Flt Permitted 0.689 0.955 0.459 0.311
Satd. Flow (perm) 0 1283 1583 0 1570 0 863 3571 0 574 3491 0
Right Turn on Red No No No No
Satd. Flow (RTOR)
Link Speed (mph) 25 25 35 35
Link Distance (ft) 306 419 825 530
Travel Time (s) 8.3 11.4 16.1 10.3
Peak Hour Factor 0.72 0.72 0.72 0.73 0.73 0.73 0.89 0.89 0.89 0.85 0.85 0.85
Heavy Vehicles (%) 2% 2% 2% 3% 3% 3% 1% 1% 1% 3% 3% 3%
Adj. Flow (vph) 25 7 28 18 7 107 11 908 9 68 427 11
Shared Lane Traffic (%)
Lane Group Flow (vph) 0 32 28 0 132 0 11 917 0 68 438 0
Enter Blocked Intersection No No No No No No No No No No No No
Lane Alignment Left Left Right Left Left Right Left Left Right Left Left Right
Median Width(ft) 0 0 12 12
Link Offset(ft) 0 0 0 0
Crosswalk Width(ft) 16 16 16 16
Two way Left Turn Lane
Headway Factor 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
Turning Speed (mph) 15 9 15 9 15 9 15 9
Number of Detectors 1 2 1 1 2 1 2 1 2
Detector Template Left Thru Right Left Thru Left Thru Left Thru
Leading Detector (ft) 20 100 20 20 100 20 100 20 100
Trailing Detector (ft) 0 0 0 0 0 0 0 0 0
Detector 1 Position(ft) 0 0 0 0 0 0 0 0 0
Detector 1 Size(ft) 20 6 20 20 6 20 6 20 6
Detector 1 Type Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex Cl+Ex
Detector 1 Channel
Detector 1 Extend (s) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Detector 1 Queue (s) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Detector 1 Delay (s) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Detector 2 Position(ft) 94 94 94 94
Detector 2 Size(ft) 6 6 6 6
Detector 2 Type Cl+Ex Cl+Ex Cl+Ex Cl+Ex
Detector 2 Channel
Detector 2 Extend (s) 0.0 0.0 0.0 0.0
Turn Type pm+pt NA pm+ov Perm NA pm+pt NA Perm NA
Protected Phases 7 4 5 8 5 2 6